Permit Specialist Review
Approved
<p class="pf0"><span class="cf0">INSPECTIONS ARE CONDUCTED BY ENGINEERING BEFORE ANY GROUND DISTURBANCES RELATIVE TO CONSTRUCTION MAY COMMENCE. THE BUILDING DIVISION DOES NOT SCHEDULE THESE INSPECTIONS. YOU WILL NEED TO CONTACT ENGINEERING/STORMWATER CAN BE REACHED AT (352) 527-5446. THIS WILL BEYOUR FIRST INSPECTION. PLEASE CONTACT ENGINEERING BEFORE YOU BEGIN WORK. THANK YOU. </span></p>
Addressing Review
Approved
Engineering FFEA Review
Approved
Environmental Health Review
Approved
<p class="pf0"><span class="cf0">SEPTIC SYSTEM APPROVAL MUST BE PROVIDED AT THE TIME OF FINAL INSPECTION PRIOR TO CO ISSUANCE. </span></p>
Plans Examiner Review
Request for Information
04-01-2025DigEplan Review
1- Front door orientation on energy calcs does not match site plan. Worst case not given. Site plan show NW, energy calcs list S, these must match. FBCE 403.7.1 <div>2- Provide truss review letter from the building designer. FBCR 802.10.2</div><div>3- Provide truss profile pages and layout for building review. FBCR 802.10.2</div><div>4- Per Manual S, both units oversized per FBCE 403.7.1.1. Must be between 90%-115%</div><div>5- Indicate landing at garage service door. FBCR 311.3</div><div>6- Provide framing detail for stair landing FBCB 107.2.1</div><div>7- Indicate smoke detector on 1st floor FBCR 314.3(3)</div><div><br></div>
Driveway Review
Request for Information
04-01-2025Show D/W Apron Location on Site Plan
Must show D/W apron with flares where it meets the roadway on site plan.
Site Review
Request for Information
04-02-2025SITE MISC
MUST SHOW DW APRON ON SITE PLAN
Utility Review
Approved
<div>Lot must connect to Citrus County’s Central Water System.</div><div><div>Permitee/Owner must supply and install a pressure regulator. </div><div>If future central sewer becomes available, lot will be required to connect within 365 days of notification. </div></div><div><br></div><div><div><br></div><div>Water meters will not be installed on a lot that is not cleared and staked. </div><div>Once the water meter is installed, it is the Permitee/Owner's responsibility to maintain the integrity of the water meter and parts. Any damage, missing parts and/or removal of the water meter will result in a minimum $250 Tampering Fee which will be added to the active permit. See County Code: Sec. 102-140. - Damaging, tampering with, or altering service unit's facilities.</div><div>1.2.12 FINAL INSPECTION</div><div>The Permitee/Owner must request the Utility final inspection of the project after all construction activities are completed.</div></div><div><br></div>
Review Consolidation
Request for Information
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
04-08-2025PERMIT REVIEW COMMENT
Per PLAN, ROAD & SITEPLAN review denial comments:<div><div><div>PLAN review denial comments:</div><div>1- Front door orientation on energy calcs does not match site plan. Worst case not given. Site plan show NW, energy calcs list S, these must match. FBCE 403.7.1 <div>2- Provide truss review letter from the building designer. FBCR 802.10.2</div><div>3- Provide truss profile pages and layout for building review. FBCR 802.10.2</div><div>4- Per Manual S, both units oversized per FBCE 403.7.1.1. Must be between 90%-115%</div><div>5- Indicate landing at garage service door. FBCR 311.3</div><div>6- Provide framing detail for stair landing FBCB 107.2.1</div><div>7- Indicate smoke detector on 1st floor FBCR 314.3(3)</div><div><br></div></div><div><br></div><div>ROAD review denial comments:</div>Must show D/W apron with flares where it meets the roadway on site plan.</div><div><br></div><div>SITEPLAN review denial comments:</div>MUST SHOW DW APRON ON SITE PLAN</div>
Review Distribution
Approved
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
Plans Examiner Review
Approved
| Assigned to Reviewer: Stephen R Switzer stephen.switzer@citrusbocc.com |
Driveway Review
Request for Information
| Assigned to Reviewer: DARIN M WILSON |
04-09-2025Road Misc.
Must show apron with flares where it meets the roadway.
Site Review
Request for Information
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
04-09-2025SITE MISC
D/W APRON FLARES MUST BE LOCATED OUTSIDE THE PROPERTY LINE
Review Consolidation
Request for Information
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
04-10-2025PERMIT REVIEW COMMENT
Per ROAD and SITEPLAN review denial comments:<div><div>ROAD review denial comments:</div><div>Must show apron with flares where it meets the roadway.</div><div><br></div><div>SITEPLAN review denial comments:</div>D/W APRON FLARES MUST BE LOCATED OUTSIDE THE PROPERTY LINE</div>
Review Distribution
Approved
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
Driveway Review
Approved
Swale'd apron to allow for proper drainage from high to low side of entire property frontage within the ROW.
Site Review
Approved
<b>***SITE APPROVED FOR SFD ONLY - MUST MAINTAIN MIN OF 4 TREES ON SITE***</b>
Review Consolidation
Approved
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
Pre Permit Issuance Review
Missing Information
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
04-11-2025PERMIT REVIEW COMMENT
ALL SUBCONTRACTORS MUST BE SIGNED ON TO PERMIT PRIOR TO ISSUANCE
Pre Permit Issuance Review
Missing Information
| Assigned to Reviewer: Shannon Lutton shannon.lutton@citrusbocc.com |
04-21-2025PERMIT REVIEW COMMENT
ALL SUBCONTRACTORS MUST BE SIGNED ON TO PERMIT PRIOR TO ISSUANCE