12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
The proposed parcel do not currently exist and would need to be created thru the plating process. Approval cannot be granted till parcels are created. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
The driveways along the internal access drives would need to meet a 125-foot separation from other driveways. (Section 7140 Table 7-1) If the applicant can demonstrate that traffic safety will not be unduly impaired, the Director of Public Works may approve a reduced connection spacing up to a maximum of 20 percent of the required spacing. Revise the plans to meet the required spacing or submit a request for reduced connection spacing with appropriate justification. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
In accordance with condition number 12 of Ordinance 2022-A35, each parcel will be required to have a sidewalk connecting from their parking lot to the sidewalk in the County right-of-way. Revise and resubmit. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
In accordance with Section 6310.A.7, provide calculations demonstrating that the conveyance systems (inlet and pipe) are designed for a minimum 10yr/24hr storm event unless reasoning for an alternative criteria is provided, and is acceptable to the County. Design parameters including time of concentration, tailwater, Manning's Coefficient and inlet capacity calculations are required. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
The Infrastructure permit number 202205044 shows 2.88 acres of impervious in the ISR table, the table on C-101 of this set of plans shows 2.2 acres, please clarify which is correct. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
In order to demonstrate compliance with PUD-22-01, please update the table to include the total area of impervious for the subject parcel and the cumulative table for all of the parcels draining to the retention pond permitted by SWFWMD. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
Sheet C-302, Revise vehicle movement plan to include complete route entering and exiting county roads. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
Sheet C 301, Note states a special emphasis crosswalk but the detail shows standard, which one will be installed? Please review and revise. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
03-16-2023
SWFWMD minor modification letter states an incorrect master development plan name. Please review and revise. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)
12-30-2022ENG MISCELLANEOUS CALL 5247
007030-Additional comments may be made after re-submittal. (Bill Laflamme, Engineer I, Engineering Division, 352-527-5443)